High NA Optical Fiber

Features:

  • High Numerical Aperture
  • Reduce Bending Loss for smaller diameter
  • Dual UV-Cured Acrylate Coating
  • Low splice loss with standard fiber

Geometrical Properties

  • Cladding diameter (Type A)
  • 125 ± 2.0µm
  • Cladding diameter (Type B)
  • 125 ± 2.0µm
  • Cladding diameter (Type C)
  • 125 ± 2.0 µm
  • Core to clad connectivity error (Type A)
  • <1.0 µm
  • Core to clad connectivity error (Type B)
  • <1.0 µm
  • Core to clad connectivity error (Type C)
  • <1.0 µm
  • Coating diameter (Type A)
  • 250 ± 10 µm
  • Coating diameter (Type B)
  • 250 ± 10 µm
  • Coating diameter (Type C)
  • 250 ± 10 µm

Optical Characteristics

  • Operating wavelength (Type A)
  • 1310 nm
  • Operating wavelength (Type B)
  • 1550 nm
  • Operating wavelength (Type C)
  • 1550 nm
  • Cut off wavelength (Type A)
  • <1260 nm
  • Cut off wavelength (Type B)
  • <1500 nm
  • Cut off wavelength (Type C)
  • <1500 nm
  • Mode field diameter (Type A)
  • 6.7 ± 0.5 µm
  • Mode field diameter (Type B)
  • 7.9 ± 0.5 µm
  • Mode field diameter (Type C)
  • 5.9± 0.5 µm
  • Attenuation at 1550 nm (Type A)
  • < 1.0 dB / km
  • Attenuation at 1550 nm (Type B)
  • < 1.0 dB / km
  • Attenuation at 1550 nm (Type C)
  • < 1.0 dB / km
  • Numerical Aperture (Type A)
  • 0.19
  • Numerical Aperture (Type B)
  • 0.19 or 0.21
  • Numerical Aperture (Type C)
  • 0.29+/-0.01
View More

Mechanical Properties

  • Minimum diameter (Type A)
  • 12 mm
  • Minimum diameter (Type B)
  • 12 mm
  • Minimum diameter (Type C)
  • 12 mm
  • Proof test level (Type A)
  • 100 kpsi (1%)
  • Proof test level (Type B)
  • 100 kpsi (1%)
  • Proof test level (Type C)
  • 100 kpsi (1%)
  • Standard length (Type A)
  • 1000 meter
  • Standard length (Type B)
  • 1000 meter
  • Standard length (Type C)
  • 1000 meter

Applications

  • Device Fabrication
  • Laser Pigtailing
  • Fiber Grating Fabrication
  • Interferomertic Sensors